EU: Misbehavior reporting - Secure Internet (ITS)

Description:

This solution is used within Australia and the E.U.. It combines standards associated with EU: Misbehavior reporting with those for I-I: Secure Internet (ITS). The EU: Misbehavior reporting standards include upper-layer standards required to support misbehavior reporting services. The I-I: Secure Internet (ITS) standards include lower-layer standards that support secure communications between ITS equipment using X.509 or IEEE 1609.2 security certificates.

Relevant Regions:

Comm Profile: I-I: Secure Internet (ITS)

Comm Class: WAN - Wide Area Network

Standards in Profile:
LevelStandard
AccessInternet Subnet Alternatives
MgmtBundle: SNMPv3 MIB
SecuritySecure Session Alternatives
TransNetInternet Transport Alternatives
TransNetIP Alternatives

Data Profile: EU: Misbehavior reporting

Standards in Profile:
LevelStandard
FacilitiesETSI 103 460 Malicious behavior detection
ITS Application EntityApplication Specific
SecurityETSI 103 460 Malicious behavior detection

Solution Issues Severity: 17

The severity issue score calculation only includes issues associated with standards that are included by default.

Solution Issues:

DefaultSeverityNameTypeDescription
FalseMediumOption not standardizedStandardization GapThe option set includes at least one option that is not (yet) defined in a standard.
FalseMediumUncertainty about trust revocation mechanismSecurity GapThe mechanisms used to prevent bad actors from sending authorized messages is unproven.
TrueMediumOutdated security referenceSecurity GapThe standard solution includes an outdated security reference.
TrueMediumPerformance not fully defined (medium)ITS Info GapThe performance rules are not fully defined for this information flow.
TrueMediumSecure data access not providedSecurity GapThe solution does not define rules on how the application entity authenticates requests to accept or provide data.
TrueHighDraft not available (Critical)Standardization GapThe standards development organization has established a work item for the subject standard but a draft is not available for this critical feature to enable the interface. The draft may be missing due to the work item being new or simply a lack of activity on the work item.

Solution to Triples

SourceFlowDestination
ITS Object misbehavior report Cooperative ITS Credentials Management System